| Key Data Set Information | |
| Location | FI |
| Geographical representativeness description | FI |
| Reference year | 2025 |
| Name |
|
| Use advice for data set | Studied system covers the following steps of life cycle according to EN 15804: A1 Raw material supply, A2 Transport, A3 Manufacturing, A4 Transportation of the product to construction site, A5 Installation to building, C1 Deconstruction, C2 Transportation of end-of-life C3 Waste processing and C4 Disposal. In addition, the benefits and loads beyond the system boundary of stage D consist of product reuse, recovery and recycling. |
| Technical purpose of product or process | The Lumon Roof product family consists of three roof models: Siro, Klassinen, and Tasa. The Lumon roof is attached to the building's wall. Frame: The posts of the frame system are placed in the corners of the terrace. As the loads increase, the profiles automatically change to stronger ones. Side or center posts can also be added. Side posts can be selected both inside and outside the horizontal beams. Posts supporting the rear beam are placed next to the wall. The front and rear beams support the roof beams to which tempered glass panels are attached. The aluminum profiles are powder coated. Roof: The glass panels of the roof can be divided if needed. The glass joint consists of two profiles glued to the glass and a seal. The maximum dimensions of the glass panel are 4500x1000mm. The roof glass consists of at least 8 mm tempered glass. If necessary, 6 mm thick tempered glass is installed in the gable triangles. EPDM rubber seals are installed between the glass roof and the wall. Eaves: For a sloping roof, side and front eaves can be selected. Side eaves can be attached as an overhang to the outermost roof beams. The width of the side eaves is 250 mm. The glass is attached to the side eaves piece from the outer edges. When selected, the front eaves measure 320mm. Accessories: Sun protection blinds are available for the roof. The blinds come in two colors: white and gray, both completely opaque. Aluminum L-angle is used as snow guard. Rainwater is directed to the desired edge with integrated gutters and downpipes. LED lights including power supply and LED strips. Sheet metal coated with plastic in RR shade is used for flashing and water management. |
| General comment on data set | Allocation rules used are made according to the ISO14044:2006. Allocation is avoided when possible and when necessary, allocation is made based on physical shares and also avoiding double calculations. Allocation is required if the production process produces more than one product and the flows of materials, energy and waste cannot be separately measured for the studied product. Allocation used in generic data sources follow the requirements of the EN 15804 -standard. It should be noticed that the allocation method ‘allocation, cut-off by classification’ has been used for Ecoinvent 3.8 data, which complies with EN 15804. Avoiding allocation could not be avoided for following inputs as the information was only measured on factory process level. • Electricity consumption, heat production, transport fuels: only measured on factory level. • Energy-, mixed-, bio-, wood-, aluminium-, mixed metal-, cardboard-, plastic-, glass-, hazardous-, construction waste: only measured on factory level. • Water use: only measured on factory level. • Ancillary materials; fluids, sandblasting sand and nitrogen: only measured on factory level. • Packaging materials: only measured on factory level. The inputs were allocated to studied product based on production volume (mass in kilograms). According to EN 15804, flows leaving the system at the end-of-waste boundary of the product stage (A1- A3) are allocated as co-products. According to EN 15804, process that has a very low contribution to the overall revenue may be neglected in co-product allocation. Materials sent for recycling or energy recovery from manufacturing were not allocated, as it was estimated that their contribution to the overall revenue is very marginal. No other allocations were made in this assessment. This study follows the cut-off criteria stated in RTS PCR and EN 15804 -standard. This study does not exclude anu components or processes which represent more than 1 % of the emissions of studied life cycle stage. The study does not exclude any hazardous materials or substances. Excluded processes and the criteria for exclusion are given in following table. Machines and facilities (capital goods) required for and during production are excluded, as is transportation of employees. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2030 |
| Time representativeness description | "2025-06-30" - "2030-06-30" |
| Technological representativeness | |
| Type of data set | EPD | ||||
| Subtype | representative dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-07-31T17:04:53 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 82d717a2-17e9-457f-acdb-b7f087d06973 |
| Date of last revision | 2025-07-15T09:36:22.2184292Z |
| Data set version | 00.03.000 |
| Registration authority |
EPDFinlandRTS
|
| Registration number | RTS_257_23 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
| |
Indicators of life cycle