RTS Finland
Data stock: PUBLIC [ Download ]

Process data set overview page

Data set: Future Ventilation Unit: Liquid Circulation, i.e., Radiator Heat Recovery 1 m3/s (00.03.000)

Full name
Future Ventilation Unit: Liquid Circulation, i.e., Radiator Heat Recovery 1 m3/s
Location
FI
Reference year
2025
Valid until
2030
Reference flow(s)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Synonyms
Use advice for data set
The system boundaries for the EPD are of the type 'Cradle to gate with options, including modules C1-C4 and module D.' The product system being studied covers the product stage of the Future ventilation unit (A1-A3), transportation to the construction site (A4), construction site activities in terms of handling packaging waste (A5), and the end-of-life stage (C1-C4). Modules B1-B7 are not considered relevant. Additionally, impacts outside the lifecycle (D) are considered in the assessment. The production and manufacturing of machinery and equipment required during production (production utilities) are not taken into account, nor are employee transportation.
Data set use approval
General comment
Allocation has been made according to the standard ISO 14044:2006 and the standard EN 15804. Information on energy consumption, packaging materials, and production waste was obtained for all Future products produced at the entire plant for the last full production year of 2023. The input data has then been presented per production unit using the revenue data of Future products manufactured at the plant. Allocation was done based on revenue, as precise physical data, for example, the mass of all sold products, is not available. The process produces by-products such as metal scrap, including steel, aluminum, and copper. Some of the production emissions have been allocated to these streams. Other waste streams have been considered within the product system. In accordance with standard EN 15804, the biogenic carbon flows of packaging materials follow the physical mass flows of the production process. The scope of the work follows the cut-off criteria set out in standard EN 15804 and the RTS protocol guidelines, and the lifecycle inventory data includes at least 95% of total inflows (mass and energy) per module. In this study, no input or output flows have been excluded.
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
  • Independent external review by
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
KOJA Oy
Technical purpose
The primary purpose of the Future product family's ventilation units is ventilation, replacing used air in a building or part of a building with fresh outdoor air. Ventilation units can perform multiple functions, such as air filtration, heat recovery, heating and cooling, as well as humidification and dehumidification. The Future series ventilation units are delivered as modular or pre-assembled units, and can be adapted to various buildings, environments, and usage needs. The unit is composed of steel modules, within which different components such as intake and exhaust air filters, heat recovery devices, heat exchangers, fans, and sound attenuation elements are installed. The example unit in this environmental declaration includes shutoff, filtration, heat recovery, post-heating, fan, and sound attenuation functions. Finished units can be delivered in parts, modules, or as complete assemblies. Some functions, such as the machine base, can be assembled and installed only at the construction site. The ventilation units of the Future product family can be equipped with electrical automation either at the factory or at the construction site. Product weights: 1 m3/s: 818 kg/unit 5 m3/s: 2713 kg/unit
Input Products
No records found.
Co-Products
No records found.
Data set version
00.03.000
Time stamp (last saved)
2025-12-08T12:36:44
Data set format
Compliance systems
  • EN 15804+A2 (Overall compliance: Fully compliant)
  • ISO 14025 (Overall compliance: Fully compliant)
  • ISO 21930 (Overall compliance: Fully compliant)
Tag