Data set: Phi Modul 1640-1700, 15-48 W DALI & On/Off (00.03.000)
A more recent version of this data set exists in the database.
Most recent version of this data set:
00.03.001
View entire data set
Download data set as XML file
Download as ZIP file
Full name
Phi Modul 1640-1700, 15-48 W DALI & On/Off
Location
FI
Reference year
2023
Valid until
2028
Reference flow(s)
Phi Modul 1640-1700, 15-48 W DALI & On/Off - 1.0 * 1.0 Stück (Number of pieces)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Synonyms
Use advice for data set
This EPD covers the following modules; A1 (Raw material supply), A2 (Transport), and A3 (Manufacturing). The construction stage includes module A4 (Transport to the site). The use phase includes module B6 (energy consumption). In addition, the end-of-life stage is included information from C2, C3, and C4 and beyond the life cycle information from D module. B4 module has been left out because calculations are based on reference lifetime of the luminaire and during that period there is no need for replacements for parts. A1-A3 Manufacturing A1 raw material supply, the module takes the acquisition and processing of both base materials and the prefabricated components that make up the product. A2 transportation module includes the transportation of different materials and components from the manufacturer to the factory where the final product is made (Oulu, Finland). A3 manufacturing module includes the consumption of energy and packaging material used during the manufacturing process. Electricity energy consumed is from certified renewable hydropower. The primary data used has been obtained from the production plant itself. A1-A3 states consider waste management of production waste. Production waste scenarios are municipal waste treatment in Finland. No secondary fuels or materials are used in production. A4-A5 Installation stage The information from transportation A4 is included in the LCA calculation. Modul includes transportation of the finished and packaged product. The transportation distance is 500 km with a truck. Module A5 installation process includes transport and management of packaging waste. Installation is considered in EPD. Installation takes into account the materials necessary for installation, but excluding energy used in installation. B1-B7 Use stage B1 includes the environmental aspects and impacts of the normal use of the product, not including the consumption of water and energy. The impact of the product at this stage is null. B2 maintenance is not considered. B3-reparation is not considered. B4 substitution is not considered B5 rehabilitation is not considered B6 operational energy use is considered in EPD. C1-C4 End-of-life stage The information from the transportation of waste C2 is included in the LCA calculation, the average distance to the recycling center is 100 km. C3 Waste management. C4 Final disposal module considers the treatment of the rest of the product. The final disposal is incineration and landfill. D Benefits and loads beyond the system boundary This product claims environmental benefits due to recycling according to Directive 2012/19/EU of WEEE. Approximately 90.4% of luminaire ends up to recycling according to Eurostat recycling rate for large electronic equipment. Luminaire is dismantled into metals, plastics and electronics. An assumption is made that 90% of metal is recycled, 55% of plastics are recycled and 94,1% of SER waste is recycled.
Data set use approval
General comment
Product specific data was collected directly from manufacturers production plant. The data represent year 2022. Production phase electricity and heat consumption data was collected in 2021 and production phase waste flow data was collected 2020. Quality of data is considered to be good. Allocation in production energy consumption and waste streams are based on annual production rate. Energy consumption and production phase waste streams are calculated by dividing annual energy consumption rate and annual waste mass by the annual production volume. Pallet has been allocated for one luminaire by taking account how many luminaires can fit into one wooden EUR pallet. The study is Gradle to gate with options, modules C1-C4, and module D. The study includes all modules which are stated mandatory in the EN 15804 A1:2012+A2:2019 and RTS PCR 2020. The table below shows what actions study includes and excludes. Included Production of the component and packaging (A1) Transport to manufacturing (A2) Electricity, heat and waste from manufacturing (A3) Transport of products to client (A4) Installation of luminaire(A5) Energy consumption of use phase (B6) Disassembly of product (C1) Transport to disposal (C2) Disposal, dismantling and treatment of waste (C3-C4) Avoided production of raw materials if recycled (D) Excluded Production of machines Transport of returned products Labor and related aspects Business travel Research and development activities Use phase emissions to environment (B1) Maintenance (B2) Repair (B3) Replacement (B4) Refurbishment (B5) Operational water use (B7)
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
Independent external review by
Heini Koutonen, Nordic Offset Oy
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
Greenled Oy
Technical purpose
EPD is made for one luminaire (Family). The EPD covers all length variations of Phi Linear, Vision, and Vision Direct/Indirect. Phi Modul covers three length variations. The life cycle assessment of the product group variations does not differ by more than 10 % (GWP total, A1-A3), see paragraph 2. Products described in this EPD are: Phi Linear Phi Modul Phi Vision Phi Vision Direct/Indirect Phi Linear is a cost-effective microprism luminaire with an evenly illuminating light surface. It is ideal for retail and clean industrial settings. Phi Vision is an elegant microprism luminaire with an evenly illuminating light surface. It is ideal for offices and schools. The textured surface and impeccable finishing give the luminaire a high-quality, premium look. Phi Vision has a wide aperture that enables soft and glare-free lighting. Phi Modul is a microprism luminaire with an evenly illuminating light surface. It has been particularly designed for Tego ceiling systems. This luminaire offers a cost-effective way to integrate lighting into a Tego system. Phi Modul Length: 1340-1400mm*,1640-1700mm*,1840-1900mm* Led color temperature: 3000 K, 4000 K*, 5000 K Led color rendering index: CRI 80*, CRI 90 Light distribution: MP90(D90), MP80*(D80) Dimmability: DALI*, On/Off Frame color: Powder painted
Input Products
No records found.
Co-Products
No records found.
Data set version
00.03.000
Time stamp (last saved)
2024-01-10T16:39:47
Data set format
Other versions
00.03.001
Compliance systems
EN 15804+A2 (Overall compliance: Fully compliant)
ISO 14025 (Overall compliance: Fully compliant)
ISO 21930 (Overall compliance: Fully compliant)
Tag
Registered in
Process is not registered in any registry
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.
Yes
No