Data set: Casette fan coils with steel front panel - PMFC 10/14- MP (00.04.000)

Full name
Casette fan coils with steel front panel - PMFC 10/14- MP
Location
FI
Reference year
2025
Valid until
2030
Reference flow(s)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Synonyms
Use advice for data set
The system boundary is cradle to gate with options, module A4, modules C1-C4 and module D and includes the following life cycle stages: • A1: Raw material supply includes raw material extraction and raw material processing to semi-finished product; • A2: Raw material transport from suppliers to manufacturing; • A3: Manufacturing includes direct emissions from the site and the production of energy, fuels, and packaging materials; • A4: Transport to construction: Transport to the site • A5: Construction – installation of the product into a building and waste treatment of used packaging materials; • B4: Use phase- change of parts of the operation of the fan coil unit; Replacement scenario of B4: Filters are replaced seven (7) times during fan coils service lifetime. • B6: Use phase- operational energy the energy consumption from the operation of the fan coil unit; Finnis average grid mix is applied for energy use. Use scenario of B6: 6 months/year cooling with full power during full reference service life • C1-C4 End of life: Deconstruction (C1), transport of product to end of life (C2), end of life waste processing for recycling and energy recovery(C3) and the disposal of materials (C4), and; • D: Reuse, recycling and recovery potential outside the system boundaries from material and energy substitution.
Data set use approval
General comment
Mass-based cut-off criteria is adhered to. The cut-off rule is reflected in the inputs of the product system studied separately for each module. Flows accounting less than 1% of the overall input mass or energy flows are excluded from the study if appropriate LCI data or even proxy data is not available. The sum of excluded flows should not exceed 5% of the total inflows (by mass or by energy). The flows knowingly excluded from the study are as follows: - Capital equipment, infrastructure and employee commute are excluded.
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
  • Independent external review by
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
Pemtrade Oy
Technical purpose
This declaration is made for casette fan coils, with trademark of PMFMC. Studied fan coils have four different product ranges: PMFC10/14-MP, PMFC 17/21-MP, PMFC 28/32-MP and PMFC 36/42-MP. The products consist of consist of steel frame and front panel, condensate drain basin with molded ABS, NBR-rubber insulation, heat exchanger (aluminium and copper), electronics (drain pump, electric motor, cables and control PCB), fan (PA), fine filter (PET and fleece) and filter (PE). Products are used for cooling applications of various indoor spaces. Studied fan coils are water fan coils units, i.e., they have one heat exchanger through which chilled waters flow for cooling.
Input Products
No records found.
Co-Products
No records found.
Data set version
00.04.000
Time stamp (last saved)
2025-08-13T08:48:23
Data set format
Compliance systems
  • EN 15804+A2 (Overall compliance: Fully compliant)
  • ISO 14025 (Overall compliance: Fully compliant)
  • ISO 21930 (Overall compliance: Fully compliant)