RTS Finland
Data stock: PUBLIC [ Download ]

Process data set overview page

Data set: Balcony doorset (00.03.000)

Full name
Balcony doorset
Location
FI
Reference year
2022
Valid until
2027
Reference flow(s)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Synonyms
Use advice for data set
The system boundary is cradle to gate with options, modules C1-C4 and module D and includes the following life cycle stages: • A1: Raw material supply includes raw material extraction, forestry operations and raw material processing to semi finished product; • A2: Raw material transport from suppliers to manufacturing; • A3: Manufacturing includes direct emissions from the site and the production of energy, fuels, water and packaging materials; • A4: Transport to construction; • A5: Construction – installation of the product into a building and waste treatment of used packaging materials; • C1-C4 End of life: Deconstruction (C1), transport of product to end of life (C2), end of life waste processing for recycling and energy recovery(C3) and the disposal of materials (C4), and; • D: Reuse, recycling and recovery potential outside the system boundaries from material and energy substitution.
Data set use approval
General comment
Mass-based cut-off criteria is adhered to. The cut-off rule is reflected in the inputs of the product system studied separately for each module. Flows accounting less than 1% of the overall input mass or energy flows are excluded from the study if appropriate LCI data or even proxy data is not available. The sum of excluded flows should not exceed 5% of the total inflows (by mass or by energy). The flows knowingly excluded from the study are as follows: - - Capital equipment, infrastructure and employee commute are excluded. Glass waste due to human error in the manufacturing of the doorset is excluded.
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
  • Independent external review by
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
Puutuoteteollisuus ry
Technical purpose
This declaration is made for a balcony doorset representing the typical Finnish balcony door. The balcony door provides means of moving into and out from the building while providing lighting, sufficient security and thermal insulation. The wooden balcony doorset has the dimensions of 0.99x2.28 m, a casing depth of 170 mm and with a U-value of 1.0 W/m2K. The frame and door leaf framework are pine and the threshold is hardwood. The balcony door leaf is composed of wooden framework, fiberboards and EPS insulation. The size of the glazing is M16 (1508 mm) and it is composed of a triple-glazed insulation glass unit with argon gas. The door has a mortise lock system, security hinges and aluminium cladding. The main raw materials of the balcony doorset are pine, insulating glass and fiberboard, and the product also contains aluminium sheets, metal hardware, plastic components and insulation, gaskets and surface treatment. Mass shares of different materials in the balcony doorset are shown in the table below. Mass shares of materials and the other reported results are calculated as weighted averages between the five manufacturers.
Input Products
No records found.
Co-Products
No records found.
Data set version
00.03.000
Time stamp (last saved)
2026-08-31T12:57:36
Data set format
Compliance systems
  • EN 15804+A2 (Overall compliance: Fully compliant)
  • ISO 14025 (Overall compliance: Fully compliant)
  • ISO 21930 (Overall compliance: Fully compliant)
Tag
Registered in
Process is not registered in any registry
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.